Your Muscle Puck senses the electrical activity of your muscles and tracks movement. Use Posture to build better posture habits throughout your day, or Power to see how your muscles work during exercise.
New to Muscle Puck? Start here.
Regulatory InformationShared by both apps - download the app, attach the electrode, then choose Posture or Power below.
The reusable electronic module houses the core technology and features three muscle-sensor (EMG) electrode snaps that connect to the electrode patch.

A hypoallergenic adhesive patch with three distinct conductive gel zones. It positions the electrodes correctly and keeps them from touching, so every reading stays clean and reliable.

Keep the plastic liner on for now. Align the Puck with the three snaps on the patch and press to snap it securely - a stable mechanical and electrical connection for accurate EMG reading.

Remove the backing liner from the electrode patch.

Position the patch so the conductive zones sit flush against your skin, over any muscle you want to track. Apply gentle pressure for full skin contact.

For the best signal:
Not sure where to place it? View the Muscle Placement Guide →
Muscle Puck measures the electrical signal traveling through the muscle. The two upper sensing electrodes should run along the direction of the muscle fibers.

✕ Incorrect - sensing electrodes turned across the muscle
✓ Correct - sensing electrodes aligned along the muscle
Wear your Muscle Puck on your upper back throughout the day. It monitors both your back angle and your muscle activity and gives you a gentle vibration when you've been in poor posture for too long.
Set up Posture →Place your Muscle Puck on the muscle you want to measure during exercise. Power combines muscle activity, movement and camera-based pose tracking so you can see how your muscles work while you move.
Set up Power →Your hydrogel electrodes can typically be reused 5-10 times, depending on skin contact and cleanliness.
After use:
Replace the electrode when it becomes dirty, loses adhesion or no longer makes reliable contact with your skin.
Try these first:
Make sure the Puck is positioned over the muscle rather than a bone or joint.
The two sensing electrodes should run along the direction of the muscle.
All electrodes need good contact with your skin.
If you're reusing an electrode, make sure it still adheres well and hasn't become excessively dirty or dry.
Contract the target muscle deliberately and see whether Power detects the activation. A slow bicep curl is an easy way to test your setup.
Still having trouble? Contact Support
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Longevity Quantified may void the user's authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.